    面向大气超细颗粒物监测网的双极粒径谱仪研究

    Research on the bipolar SMPS for atmospheric ultrafine particles monitoring networks

    • 摘要: 大气超细颗粒物对人体健康和全球气候有显著影响。世界卫生组织建议开展体系化的超细颗粒物数浓度和粒径谱监测,欧盟对此已出台相关的政策指令。本研究自主研发的双极粒径谱仪能在线测量超细颗粒物粒径分布(如10~700 nm),并同时在线测量超细颗粒物的数浓度。传统粒径谱仪所使用的固定荷电分布参数无法反映颗粒物荷电分布的动态变化,针对这一问题,该双极粒径谱仪通过改进硬件和反演方法,可获取大气颗粒物的动态荷电分布并将其应用于数据分析,还能利用所测超细颗粒物数浓度作为粒径分布的参比指标,保障数据质量。与参比粒径谱仪的对比验证结果表明,两者得到的总数浓度相关性较好(R2=0.928)。利用该型双极粒径谱仪在北京进行了为期8年的外场观测,并在全国14个城市、郊区和清洁站点开展了为期1年的组网观测。所有仪器在投入观测前均进行了实验室标定,所测粒径分布与参比粒径谱仪测量结果的偏差在±10%内。观测期间,仪器运行稳定,各站点粒径分布积分数浓度与总数浓度的比值的中位数介于0.82~1.21之间。未来,该仪器有望为京津冀地区大气超细颗粒物监测网建设提供关键技术支撑。

       

      Abstract: Atmospheric ultrafine particles have great impacts on human health and global climate. The World Health Organization recommends conducting systematic monitoring of ultrafine particles in terms of number concentration and size distribution,and the European Union has already issued related policy directives accordingly. The self-developed bipolar scanning mobility particle sizer(bipolar SMPS) enables online measurement of the particle number size distribution(PNSD)(e.g.,in the size range of 10-700 nm),as well as total particle number concentration. To address the issue that the fixed charge distribution parameters used in conventional SMPS cannot reflect the dynamic changes in aerosol charge distribution,the bipolar SMPS improves both hardware and inversion method to obtain the dynamic charge distribution of atmospheric particles and apply it to data processing.Additionally,bipolar SMPS uses the online measured total particle number concentration as a reference,thereby ensuring the data quality. The bipolar SMPS exhibited a good correlation(R2= 0. 928) for total particle number concentration compared with a reference unipolar SMPS. The bipolar SMPS has been deployed for eight years of field observations in Beijing, and further deployed in a one-year network observation across 14 urban,suburban and clean sites in China. Calibration experiments were conducted before measurement to ensure that the particle number size distribution(PNSD) remained within ± 10% of those measured by the reference SMPS. The instruments operated stably during atmospheric observations,with the median ratio of the integrated number concentration from PNSD to the directly measured total particle number concentration at each site ranging from 0. 82 to 1. 21. In the future,the bipolar SMPS is expected to provide key technical support for the construction of an atmospheric ultrafine particle monitoring network in the Beijing-Tianjin-Hebei region.

       

    /

    返回文章
    返回