高级检索

    在线监测法长周期碳排放量的不确定度评定:以焦化、烧结机头和自备锅炉电厂三处排放口为例

    Uncertainty evaluation of long-term carbon emissions by the online monitoring method:A case study of three emission outlets from coking,sintering machine head,and captive boiler power plant in the steel industry

    • 摘要: 碳市场作为实现“双碳”目标的关键政策工具,其公平、高效运行离不开准确、可靠的碳排放监测数据,而开展系统性的碳排放不确定度研究,正是保障监测数据质量、增强监测结果公信力的核心支撑。本研究以钢铁行业为例,结合误差传递法与“自上而下”(Top-Down)方法,建立了一套适用于在线监测法长周期碳排放量不确定度评定的方法,并选取A、B两家钢铁厂的焦化、烧结机头以及自备锅炉电厂三处排放口,基于连续排放监测系统(CEMS)持续一年的实际监测数据,开展实证评定。结果表明:烟气流量测量是不确定度的主导来源,对总不确定度的贡献率为81.77%~96.86%,其中速度场系数不确定度和平均流速示值不确定度是主要分量;CO2浓度相对不确定度相对稳定(1.01%~1.12%),主要来源于标气自身不确定度;各厂不同排放口间的不确定度差异显著,A厂焦化排放口总扩展不确定度最小(5.50%,k=2),B厂焦化排放口总扩展不确定度最大(13.98%,k=2)。上述结果验证了本研究所提不确定度评定方法的可行性与实用性,可为钢铁等重点行业碳排放量精准计量以及数据质量提升提供技术支撑。

       

      Abstract: As a key policy instrument for achieving the carbon peaking and carbon neutrality goals,the fair and efficient operation of the carbon market relies on accurate and reliable carbon emission monitoring data. Conducting systematic research on the uncertainty of carbon emissions is a core support for ensuring the quality of monitoring data and enhancing the credibility of monitoring results. Taking the iron and steel industry as an example,a method for evaluating the uncertainty of long-term carbon emissions measured by online monitoring system was established by combining the error propagation method with the Top-Down approach. An empirical evaluation was conducted based on one year of actual operational data from continuous emission monitoring systems(CEMS) at three emission outlets—coking,sintering machine head,and captive boiler power plant—at two steel plants,A and B. The results indicate that flue gas flow rate is the dominant source of uncertainty,contributing 81. 77% to 96. 86% of the total uncertainty,with the velocity field coefficient and the indicated average flow velocity being the main sub-components. The relative uncertainty of CO2 concentration is relatively stable(1. 01% to 1. 12%),primarily originating from the uncertainty of the calibration gas itself. Significant differences in uncertainty were observed among different emission outlets across the plants. The total expanded uncertainty for the coking emission outlet at Plant A was the lowest(5. 50%,k= 2),whereas that for the coking emission outlet at Plant B was the highest(13. 98%,k= 2). This study verifies the feasibility and practicality of the proposed method,providing technical support for the accurate measurement of carbon emissions and the improvement of data quality in key industries such as iron and steel.

       

    /

    返回文章
    返回