高级检索

    光谱法水质自动监测仪性能研究

    Study on the performance of spectroscopic water quality automatic monitoring instruments

    • 摘要: 随着生态环境监测网络数智化转型的持续推进,光谱法水质自动监测仪因响应快、无试剂、运维成本低等优势,近年来在地表水监测领域获得广泛应用。该文调研了我国光谱法水质自动监测仪的技术现状,并从中选取4种型号仪器,针对浊度、高锰酸盐指数、化学需氧量和总氮4项常规水质参数开展实验室和户外性能测试与评估。结果表明:光谱法水质自动监测仪测定标准溶液的精密度和准确度总体上较好,测定实际地表水时高锰酸盐指数、化学需氧量监测结果与手工监测结果的可比性较强;总氮测定则存在一定技术瓶颈,在标准溶液测定、与手工监测结果可比性方面均相对较差;应用于户外实际地表水监测时,在不进行任何维护的情况下能够在现场稳定运行2周以上。光谱法水质自动监测仪在短波紫外波段技术、模型算法优化和复杂水体适应性方面仍需进一步改进。

       

      Abstract: With the ongoing digital and intelligent transformation of the ecological and environmental monitoring network,spectroscopic water quality automatic monitoring instruments have been gradually promoted and applied in surface water monitoring in recent years due to their advantages such as fast response,reagent-free operation,and low maintenance costs.This paper investigates the current technological status of such instruments in China and selects four instrument models to conduct laboratory and field performance testing and evaluation for four conventional water quality parameters:turbidity,permanganate index,chemical oxygen demand,and total nitrogen.The results show that the precision and accuracy of these instruments in measuring standard solutions are generally good.For actual surface water,the monitoring results of permanganate index and chemical oxygen demand exhibit strong comparability with manual monitoring results.However,there are certain technical limitations in the measurement of total nitrogen,with relatively poorer performance in both standard solution testing and comparability with manual monitoring results.When applied to field monitoring of actual surface water,the instruments can operate stably on site for more than two weeks without any maintenance.Further improvements are still needed in short-wave ultraviolet band technology,model algorithm optimization,and adaptability to complex water bodies for spectroscopic water quality automatic monitoring instruments.

       

    /

    返回文章
    返回