Advanced Search
    Wu Jin, Liao Han, Wang Yiyang, et al. Research on the bipolar SMPS for atmospheric ultrafine particles monitoring networksJ. Environmental Monitoring in China, 2026, 42(4): 187-197. DOI: 10.19316/j.issn.1002-6002.2026.04.17
    Citation: Wu Jin, Liao Han, Wang Yiyang, et al. Research on the bipolar SMPS for atmospheric ultrafine particles monitoring networksJ. Environmental Monitoring in China, 2026, 42(4): 187-197. DOI: 10.19316/j.issn.1002-6002.2026.04.17

    Research on the bipolar SMPS for atmospheric ultrafine particles monitoring networks

    • Atmospheric ultrafine particles have great impacts on human health and global climate. The World Health Organization recommends conducting systematic monitoring of ultrafine particles in terms of number concentration and size distribution,and the European Union has already issued related policy directives accordingly. The self-developed bipolar scanning mobility particle sizer(bipolar SMPS) enables online measurement of the particle number size distribution(PNSD)(e.g.,in the size range of 10-700 nm),as well as total particle number concentration. To address the issue that the fixed charge distribution parameters used in conventional SMPS cannot reflect the dynamic changes in aerosol charge distribution,the bipolar SMPS improves both hardware and inversion method to obtain the dynamic charge distribution of atmospheric particles and apply it to data processing.Additionally,bipolar SMPS uses the online measured total particle number concentration as a reference,thereby ensuring the data quality. The bipolar SMPS exhibited a good correlation(R2= 0. 928) for total particle number concentration compared with a reference unipolar SMPS. The bipolar SMPS has been deployed for eight years of field observations in Beijing, and further deployed in a one-year network observation across 14 urban,suburban and clean sites in China. Calibration experiments were conducted before measurement to ensure that the particle number size distribution(PNSD) remained within ± 10% of those measured by the reference SMPS. The instruments operated stably during atmospheric observations,with the median ratio of the integrated number concentration from PNSD to the directly measured total particle number concentration at each site ranging from 0. 82 to 1. 21. In the future,the bipolar SMPS is expected to provide key technical support for the construction of an atmospheric ultrafine particle monitoring network in the Beijing-Tianjin-Hebei region.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return